Notifier M700 Addressable Manual Call Point
£46.72
Summary
The Notifier M700KAC-FG and M700KACI-FG are analogue addressable call points designed to provide a manual alarm interface for Notifier’s fire alarm control panels. These call points feature a unique ‘Plug & Play’ installation concept that reduces installation time and ensures flexibility and compliance with the latest standards. They offer options for both break glass and re-settable operating elements, with an integral LED to indicate activation.
The M700KACI-FG includes an integral loop isolator for enhanced system integrity, while both models are fully compliant with EN54, Part 11 standards, supporting either semi-flush or surface mounting. The call points are designed for use in indoor environments and feature enhanced aesthetics and backward compatibility with existing systems.
Features
- Plug & play installation designed to reduce installation time with a terminal block for easy wiring and a simple ‘plug and play’ mechanism
- Offers the flexibility to use either break glass (supplied) or re-settable operating elements for manual alarm activation
- Precise and reliable communication with Notifier’s fire alarm control panels
- Can be installed either semi-flush or surface-mounted, depending on the application
- Fully compliant with EN54, Part 11 fire detection and alarm systems standards for manual call points
- Designed to be compatible with existing systems, making integration into current setups straightforward
- Integral LED indicator provides a clear visual indication when the call point is activated
- The M700KACI-FG model includes an integral loop isolator for enhanced system integrity
- Modern design to blend with various building environments
- Optional transparent hinged cover and cover seal to prevent accidental or unauthorised activation
Specifications
- Dimensions:
- Semi-Flush Mounting: 89mm (W) x 93mm (H) x 27.5mm (D)
- Surface Mounting: 89mm (W) x 93mm (H) x 59.5mm (D)
- Weight:
- Flush Mounting: 110g
- Surface Mounting: 160g
- Mounting Hole Centres: 60mm
- Current Consumption:
- Quiescent (without isolator): 260µA
- Quiescent (with isolator): 360µA
- Alarm Current: 6mA (both models)
- Operating Voltage: 15V to 30V DC maximum
- Environmental Limits:
- Operating Temperature: -30°C to +70°C
- Humidity: 0% to 95%, non-condensing
- Ingress Protection (IP) Rating: IP24D
- Mounting Options:
- Semi-Flush Mounting
- Surface Mounting with optional back box (SR1T)
- Compatibility: Compatible with Notifier’s fire alarm control panels
Downloads
- Datasheet (Adobe PDF)
Additional information
Device Type | |
---|---|
Hazardous Applications | |
Marine Applications | |
Short Circuit Isolator | |
Environment | |
Protocol | |
System Type |
Related Products
-
PS200 Hinged Cover For KAC Manual Call Points
KAC- Protects agains unwanted activations
- Clip on fitting