Texecom AEC-0001 Impaq Glass Break Detector
Summary
The Texecom AEC-0001 Impaq Glass Break provides reliable perimeter protection with unparalleled false alarm immunity. Quad real time frequency analysis coupled with digital flex detection ensure exceptional performance.
For outstanding design with a host of user friendly features, insist on the Impaq Glass Break.
Digital Signal Analysis
The Impaq Glass Break is an acoustic glass break detector designed to provide the earliest possible warning of a potential intruder by detecting the sound of breaking glass. An advanced microprocessor analyses signals digitally, processing information relating to the frequency, amplitude and timing of every sound. For maximum false alarm immunity four separate frequency bands are analysed (Quad Frequency Analysis). The Impaq Glass Break will only indicate an alarm if the signals exactly match those of a window being broken.
Digital Flex Detection
False alarm immunity is further enhanced by the use of Digital Flex Detection. This detects the low frequency pressure wave transmitted when a window is struck. An alarm signal will only be generated if a flex signal is detected, followed immediately by the shatter signal. This ensures common false alarm sources (e.g. a glass bottle breaking outside) are completely ignored.
Glass Type Selection
Different types of glass produce different acoustic responses when broken. The Impaq Glass Break features a selector switch which can be set to either Plate and Tempered or Laminated and Wired glass types.
Dual LED Indication
Dual green and red LEDs simplify set up and help reduce false alarms by indicating pre-alarm signals and providing confirmation that test mode has been initiated.
Enhanced Adjustable Coverage Pattern
The Impaq Glass Break can be mounted on walls, in corners or on ceilings for maximum flexibility. With a coverage angle of 170 ̊at distances of up to 9m, protecting several windows with one detector is fast and straight forward. Sensitivity is fully adjustable allowing each detector to be optimised for its environment.
Features
- Suited for plate, tempered, laminated & wired glass types
- Adjustable sensitivity
- Detection/disable/comfort LED
- Microprocessor technology
- EN 50131 Grade 2
Specifications
- Maximum Range : 9m (30 feet), 170˚
- Supply Voltage : 9 – 16VDC
- Current Consumption : 11mA typical
- Alarm Signalling : Normally closed (failsafe) voltage free relay contacts
- Alarm Relay : Rated at 24VDC, 50mA protected by 18Ω series resistor
- Sensor Type : Extended response electret microphone
- Minimum Window Size : 300mm x 300mm
- Glass Type Detection : Plate, Tempered, Laminated, Wired
- Glass Thickness : 2.4 – 6.4mm
- EMC : Independently certified to EN 50130-4 : 1996
- RF Immunity : No false alarms from 80MHz to 1GHz at 10V/m
Downloads
- Datasheet (Adobe PDF)
Additional information
Weight | 2.5 kg |
---|---|
Dimensions | 0.62 × 0.26 × 0.67 cm |
System Type | |
Colour | |
Device Type | |
Environment | |
Grade |