Gas Sense Industrial Nitric Oxide Detector, 100-330ppm
£444.00
Summary
The Gas Sense Industrial Nitric Oxide Detector is a reliable solution for detecting Nitric Oxide gas concentrations ranging from 100 to 330ppm.
Features
- Housed in an IP65 ABS casing for durability and protection
- Easy sensor replacement facilitated by an accessible chamber design
- Equipped with pre-alarm and dual alarm indications, each with relay outputs, and a 24Vdc output activated during alarms
Specifications
- Gas Type : Nitric Oxide (NO)
Model Number ZS-NO/100 ZS-NO/300 Part Number 47-545 47-546 Target Gas Range 0-100ppm 0-300ppm Replacement Sensor Part
NumberCY-DTX-NT-NO-PL100 CY-DTX-NT-NO-PL100 Specific Gravity (Air=1) 1.04 Sensor Lifetime 3 Years Pre-Alarm Settings (ppm)
Bold=Default010ppm,015ppm,
020ppm,025ppm,
030ppm030ppm,045ppm,
060ppm,075ppm,
090ppmAlarm 1 Settings (ppm)
Bold=Default020ppm,025ppm,
030ppm,035ppm,
040ppm060ppm,075ppm,
090ppm,105ppm,
120ppmAlarm 2 Settings (ppm)
Bold=Default030ppm,035ppm,
040ppm,045ppm,
050ppm090ppm,105ppm,
120ppm,135ppm,
150ppm - Operating Voltage: 21 – 30VDC
- Response Time: <25 Seconds
- Quiescent Current: 48mA (250mA Surge)
- Warm-Up Time: 2 Minutes
- Operating Temperature: -20°C – +50°C
- Maximum Humidity: 15 % – 90% RH
- IP Rating: IP65
- Storage Time Without Compromising Lifetime: 6 Months from date of manufacture
- Recommended Storage Temperature: 0°C – 20°C
- Gas Sensor Type: Electro Chemica
- Dimensions (mm): 174(H) x 133(W) x 75(D)
- Weight: 0.8kg
Downloads
- Datasheet (Adobe PDF)
Additional information
Weight | 1 kg |
---|---|
PPM | 100ppm, 300ppm |