Lexicomm 2 to 8 Line Networkable Disabled Refuge Panel
£690.00 – £959.33
Summary
An EVCS is a fixed, secure, bi-directional, full duplex voice communication system to assist fire fighters during emergencies in high rise buildings or large sites where radio communication cannot be guaranteed to work due to interference from the fire plasma.
Repeater compatibility
The LX228N range of master stations is specifically designed where a repeater or 2nd master station is specified. They provide a simple solution with integral networking capability. They can provide a small network of 2 panels with lines split as 8-0, 6-2, or 4-4 ratio.
Note maximum of 8 lines total.
Outstation range
The full range of Lexicomm outstations are compatible and include Type A outstations, Type B Outstations, Type C outstations and jack points for use in far and middle east applications.
Lines auto identify by flashing Red for EVCS calls, Blue for assist calls or flashing Green for Connected calls as detailed in BS 5839-9:2021.
Emergency Assistance Alarms
The Assist Call range of emergency assistance alarms is fully compatible. It has become very popular to add these devices as an integrated system. This has several benefits namely:- fault monitored wiring, fully line powered (No mains supply), battery back-up via the master station.
Assist Call Acknowledgment
BS 8300 requires that audible and visual feedback should be provided to indicate that, when the alarm has been operated, the emergency assistance call has been acknowledged and actioned. Assist Call meets this requirement and will return to alarm if not reset within two minutes.
Larger sites
The LX228N range has built in networking, so can form part of Lexicomm network on campus style sites.. A Touchscreen Master Station (ViLX-TMS-W-8) is required as the site master. Note the LX228N master can only answer local calls and cannot be used as a site master.
Product Description
The Lexicomm LX228 is a self contained enclosure housing a master handset, one to four dual line cards, power supply & battery charger and can be surface or flush mounted (using the ViLXCBZ Bezel).
The case is made from powder coated zintec, with a smoked perspex door covering the handset. 20mm cable knock-outs are provided for all necessary cables as well as space for the backup 12V VRSLA battery.
The master station is microprocessor controlled, but requires no programming on site; the panel is fitted with end of line resistors which are simply moved to the end of line when an outstation is connected.
Lines can have an accessible toilet and Type B refuge point on the same line, as the front panel RGB indicators identify which is calling, with refuge overriding emergency assist calls as required by 1 BS 5839-9:2021.
Key Features
- Simple set up, no software.
- Repeater compatible.
- Fully Compliant to BS 5839-9:2021.
- Integrated Assist Call with acknowledge meeting BS 8300.
- 1.2A Integral PSU.
- Full Duplex operation.
- Wall mount enclosure.
- Lockable handset cover.
- Expandable from 2 to 8 lines.
- Inbuilt networking.
Specifications
Power Supply and Charger
- AC Input : 230VAC +/- 10% 50/60Hz
- Internal Supply : 5V, 16V, 27V DC
- Supply : Monitored Open, Short, Fuses, High Impedance
- Protection : Deep discharge, Short, Thermal
- Battery Type : 1 x 12V 7AH VRSLA
- Mains Fuse : 240V 1A HRC
- Battery Fuse : 750mA PTC
- Charge Current : 400mA
Inputs
- Lines : 2-8 in 2 line blocks
- Remote Enable : Short to use
- End Of Line : 10KΩ
Outstation cables
- Type : Standard* / Enhanced (*Refer to BS 5839-9: 2021 for exceptions)
- Cores : 1 x 2 core radial 1mm or 1.5mm
- Distance : 500m from master station
Outputs
- Number : 2, Fault & In use
- Fault Relay : 1x Volt free NC, Com 30VDC 1A
- In Use Relay : 1x Volt free NO, Com 30VDC 1A
Controls
- Buttons : 8 Zone keys
- Zone LEDs (x8) : RGB Status LEDs
- Fault LEDs : 3, PSU, System, General
- Supply LEDs : 2, AC ,DC present
Network Cables
- Type : Standard* / Enhanced (*Refer to BS 5839-9: 2021 for exceptions)
- Cores : 2 x 2 core loops, 1mm or 1.5mm (2c Data,2c Audio)
- Distance : 500m max between panels
Standards Compliance
- EMC :
- EN 55035:2017+A11:2020
- EN 55032:2015+A1:2020
- LVD : EN IEC62368-1:2020+A11:2020
- Product Family :
- BS 5839-9:2021
- BS 9999:2017 BS 8300-2:2018
Dimensions & Weight
- Panel (HxWxD) : 300x350x95mm
- Bezel (HxWxD) : 350x400x1mm
- Cutout (HxWxD) : 305x355x85mm
- Weight : 4.2kg
Downloads
- Datasheet (Adobe PDF)
Additional information
Weight | 4.2 kg |
---|---|
Enclosure | Standard, Stainless Steel |
Device Type | |
Lines | 2, 4, 8 |
Lines | |
Networkable |
Related Products
-
Lexicomm ViLX-CBZ Master Station Semi Recess Bezel
Vox Ignis- Brush stainless bezel for Lexicomm master stations.
- Provides a professional finish.
-
Lexicomm ViLX-LC2 2-way Line Expansion Card PCB
Vox Ignis- Expands ViLX-228 master station up to 8 lines.
- Supplied with fixing screw, EOL resistor and 2 part connector.
-
Lexicomm ViLX-RAP Remote Alarm Panel
Vox Ignis- Compatible with all Lexicomm master stations.
- High volume sounder with volume control.
- Fits standard double socket box.
- Flush or surface mounting.
- Stainless steel as standard.