C-Tec CFP AlarmSense 2, 4 or 8 Zone Panel
£145.36 – £216.93
Summary
The AlarmSense® CFP two-wire fire panel is designed to work with Apollo’s AlarmSense® range of detectors, call points, sounders and beacons.
Most conventional fire systems are designed to work with two pairs of wires per zone: one pairfor detection devices such assmoke detectors, heat detectors and manual call points; the other for alarm devices such as bells, sounders or strobes. By using different voltage bands for quiescent and alarm states, AlarmSense® components can be connected to the same pair of supply wires.
When powered and controlled by the CFP two-wire fire panel, this reliable technology takes all the complexity out of fire alarm system design, leading to quicker, less expensive and more flexible installation. Research shows an AlarmSense® two-wire system can achieve a 20-25% reduction of labour over a standard four wire conventional system.
AlarmSense®devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation (HMOs).
Features
- Designed to comply with EN54 Parts 2 and 4
- Available with 2, 4 or 8 AlarmSense zone circuits (dependent on model purchased)
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
- Four conventional sounder circuits (for use with non-AlarmSense sounders)
- Integral 1.5A EN54-4/A2 compliant switch mode PSU
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones
- Two on-board relays (Fire and Fault)
- Two open-collector outputs (Remote and Reset)
- ‘Class change’ and alert inputs
- Installer-friendly design accommodates easy first fix and straightforward maintenance
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required
- Low quiescent current
- Multiple indicators
- End of line units included (one per zone)
- Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards
- Space for two x 12V 3.2Ah VRLA batteries
- Third-party LPCB tested
Specifications
- Mains supply voltage : 230V ±10% 50/60Hz
- Mains rated current : 350mA maximum
- Internal power supply : 19V – 28.5V (27V nominal), Ripple 7V maximum (battery fault)
- Total output current limited to : 1.5A @ 230Vac (ImaxA = 146mA)
- Maximum internal battery resistance : Ri max = 1.5Ω
- Supply and battery charger monitored for failure : YES (battery charger is also temperature compensated)
- Batteries monitored for disconnection and failure : YES
- Max. battery size and type : 2 x 12V 3.2Ah VRLA type, connected in series. Minimum battery size 1.2Ah
- Mains fuse : (F1) 240V 1A HRC ceramic 20mm compliant with IEC (EN60127 PT2)
- Battery fuse : 1.6A F 20mm compliant with IEC (EN60127 PT2)
- Current draw from battery (Mains failed) : 1.5A maximum
- Number of circuits : 2 (CFP702-2); 4 (CFP704-2); 8 (CFP708-2)
- Max cable length per circuit : 500 metres
- Line monitored for head out, open & short circuit faults : YES – DC monitoring
- Maximum allowable impedance (each conductor) : 20Ω
- Maximum cable capacitance (per circuit) : 0.27µF
- Max. number of detectors/manual call points per zone : 25 per zone
- AlarmSense Optical & Heat Detector Specification Quiescent current : <50µA; triggered voltage 9V nominal
- AlarmSense Manual Call Point Specification Quiescent current : <50µA; triggered voltage 5V nominal
- AlarmSense Sounder Specification : Refer to individual device specifications
- Number of circuits : 4
- End of line resistor value : 6800 ohm 5% Tol. 0.25W (blue, grey, red, gold)
- Each circuit monitored for open and short circuit : YES – reverse voltage DC monitoring. Indicated by common fault.
- Alarm voltage : 27V maximum, 20V minimum (final battery voltage)
- Sounder circuit fuses :
- Each circuit protected by resetable fuses. (200mA min. hold current; 400mA max. trip current;
- Approx. 50mA when tripped. Reset when faults removed)
- Maximum total sounder output current to all outputs : 4 x 200mA = 800mA
- Maximum No. of bells @ 25mA : 32
- Maximum No. of electronic sounders @ 20mA : 40 (sounders must be polarised)
- Aux. Fire relay output (AUX) : Voltage free single pole changeover; Max. switching current 1A; Max. switching voltage 30Vdc
- Fault relay output (FAULT) : Voltage free single pole changeover; Max. switching current 1A; Max. switching voltage 30Vdc
- Reset auxiliary output (RESET) : Non monitored, open collector type. Active during reset cycle.
- Remote auxiliary output (REM) : Non monitored, open collector type. Active during any fire condition (provided all relevant delays have expired)
- Max. sink current : 30mA each
- Max. open circuit voltage : 27Vd.c
- 24V aux power output (for use with the above) : Output protected by a resetable fuse (100mA min. hold current). Fuse resets when fault removed
- Class Change (makes sounders sound continuously) : Connect to OV to trigger. Max. input voltage 27V. (Non-latching)
- Alert (makes sounders pulse intermittently) : Connect to OV to trigger. Max. input voltage 27V. (Non-latching)
- Physical size : 380 x 235 x 96mm approx.
- Weight : 1.75kg (without batteries)