C-Tec
Know what you're looking for?
Filter Products
Manufacturer
Type
Resolution
A Rating
Alarm In/Out
Anti-Fog
Audio In/Out
Auto Aligning
B Rating
Battery
Bluetooth Controller
Built-in Mic
Built-in Speaker
C Rating
Channels
Class A Holes
Class B Holes
Class C Holes
CO Testing
Codec
Colour
White(11)
Red(1)
Stainless Steel(1)
Detection Type
Heat(1)
Multi-Sensor(1)
Smoke(1)
Device Type
Detector(3)
Cord & Handles(1)
Indication Panel(1)
Kit(2)
Overdoor Indicator(1)
Pull Cord(1)
Remote Reset(1)
Sounder(3)
Sounder/VAD(1)
Direction
Environment
Indoor(8)
IR Range
Extinguisher Type
F Rating
Face Detection
Fast Fix Base
First Aid
Hazardous Applications
No(9)
Head Removal
Heat Testing
Interconnectable
Lens
Lines
Low Level Controller
Marine Applications
No(9)
Material
Max HDD Capacity
Max Loops
1(1)
2(1)
Maximum Record Resolution
Minimum Distance
Monitor Outputs
Networkable
Optical Zoom
Photoluminescent
Pipework Diameter
PoE Ports
Power
Protocol
Apollo(1)
XP95(2)
Range
Reach
Relay
No(1)
Remote Control Test
Self-Test
Series
Short Circuit Isolator
No(3)
Yes(1)
Sign Type
Size
Smoke Testing
Stimulus Type
System Type
Conventional(7)
Addressable(3)
Wired(6)
Technology
Touchscreen
No(1)
Wireless Interlink
Showing 1–50 of 133 results
-
10-20 Zone Master Controller Available In Flush or Surface Enclosure
C-Tec- Master controller with 10 or 20 zones.
- Compatible with C-TEC’s entire range of 800 Series field devices.
- Housed in an attractive flush or surface mounetd plastic enclosure.
- Two call levels - standard (constant tone) and emergency (intermittent tone).
- Optional mute and call accept/reset buttons.
-
24V 250mA Door Release Power Supply Unit with option Detector Circuit
C-Tec- A compact Mains derived power supply unit designed to provide power to 24V DC electromagnetic door retainers.
- Optional conventional fire detector circuit which supports two x ActiV fire detectors to form a cost-effective 'stand-alone' automatic door release system.
- Maximum output 250mA.
- Trigger Release, Hold Off and Local Trigger Inputs facilitate straightforward connection to fire alarm control panels, building management systems, timers, relays and other ancillary equipment.
- Includes a manual release button, a Mains On and an Output Triggered indicator.
- Can be mounted on a standard 25mm UK double gang flush or surface back box.
-
ActiV Conventional Heat Smoke Detector
C-Tec- Third-party certified to EN54-5 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Sophisticated onboard detection algorithms help reduce false alarms by rejecting momentary abnormal readings
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A2 fixed heat, class B fixed heat, optical and multi-sensor variants also available
-
ActiV Conventional Multi-Sensor Fire Detector
C-Tec- A high-quality combined optical + heat multi-sensor offering outstanding detection performance at a very competitive price
- Third-party certified to EN54-5 & 7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and optical variants also available
-
ActiV Conventional Optical Smoke Detector
C-Tec- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price.
- Manufactured by C-TEC in the UK.
- Third-party certified to EN54-7 by Intertek.
- Wide 6-33V DC operating voltage.
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels allowing a greater than 8 year life-span.
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.
-
ActiV Mounting Base
C-Tec- Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors
- Easy to fit with lots of working space
- Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors
- Integrated detector/base locking mechanism, head removal tool and ID tag
- Simple ‘click and twist’ design
- Remote LED terminals for the optional connection to a BF318 Remote indicator
- Bright tin plated steel terminals can accept fire rated cable of up to 2.5mm in diameter
- C4408D diode and C4408 non-diode bases available*
- Compatible with C-TEC’s entire range of ActiV conventional smoke and heat detectors
-
ActiV Relay Base with Diode
C-Tec- Includes a 1A @ 24 VDC relay controlled by detector’s remote LED output
- Ideal for switching CCTV, security and door retaining systems
- Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors
- Easy to fit with lots of working space
- Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors
- Integrated detector/base locking mechanism, head removal tool and ID tag
- Simple ‘click and twist’ design
- Remote LED terminals for the optional connection to a BF318 Remote indicator
- C4408R non-diode relay base also available for use on systems that do not require head out monitoring
-
C-Tec ActiV 96dB Conventional Base Sounder
C-Tec- Third-party certified to EN54-3 (Sounders)
- Impressive 96dB(A) sound output @ 1m
- 31 selectable primary and secondary tone pairs and two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA
- Alarm Current at 18Vdc = 3.8mA
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use
- Supplied with a BF431QCP quick connect plate and detector spur wires
- IP21C rated
-
C-Tec ActiV Conventional Base Sounder VAD (C-3-8.5)
C-Tec- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs)
- Provides 'C-3-8.5' light distribution (min 0.4 lux over a 3 x 8.5m cylindrical area)
- Impressive 96dB(A) sound output @ 1m
- Includes 31 selectable primary tones and an optional secondary tone
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use
- Supplied with a BF431QCP quick connect plate and detector spur wires
- IP21C rated
-
C-Tec ActiV or Cast Detector Retrofit Decor Plate
C-Tec- An easy-to-fit 152mm diameter mounting accessory for use with ceiling mounted ActiV or CAST devices.
- Helps cover the decorating witness marks left by Grade D type Mains/Battery Alarms on system retrofits.
- Includes multiple mounting holes and a large cable entry section.
- Two K40x12 Pozi Flange PT retaining screws are supplied to secure the C-TEC ActiV or CAST device directly to the BF-DP.
-
C-Tec ActiV Surface Manual Call Point
C-Tec- Smooth-action resettable element mimics the feel of breaking glass
- Supplied with a red back box, reset key and ‘Not in Use’ label
- Red LED ‘alarm ring’ illuminates call point face upon activation
- Photoluminescent operating window remains visible for up to 5 minutes
- Note an additional BF370SFP white flush mounting plate is required if you wish to flush mount the BF370S
-
C-Tec BF318 Remote LED Indicator
C-Tec- Conventional remote LED from C-Tec.
- High intensity, wide-angle red LED.
- Include write-on label to add location information.
-
C-Tec BF319 Fire Alarm Control Panel Mains Keyswitch
C-Tec- A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
- Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
- Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
-
C-Tec BF366 24V 5A Isolatable Relay On A Plate
C-Tec- Isolating keyswitch to temporarily disable outputs when testing fire alarm system.
- LED flashes and buzzer soudners when active.
- Fits onto a standard single gang back box.
-
C-Tec BF367 Auxiliary Device Isolator
C-Tec- Isolate a 24V output for fire alarm panel.
- Prevent auxillary equipment such as autodiallers from activating.
- Label includes area to write on description.
-
C-Tec BF431A/CX/W Addressable XP95 Compatible 96dB Base Sounder
C-Tec- Impressive 96dB(A) sound output @ 1m.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- Onboard short-circuit loop isolator.
-
C-Tec BF560-24 24V 1.5A EN54-4 Switch Mode PSU in Plastic Enclosure
C-Tec- 24V 1.5A EN54-4 Switch Mode PSU.
- Plastic enclosure.
- Certified to EN54-4/A2 by the LPCB and VdS (AFNOR pending).
- Includes a single-pole voltfree changeover relay that switches for any fault condition.
- Multiple indicators - supply present, general fault, fault type & aux. equipment fault.
- Two selectable battery charge currents.
-
C-Tec BF562 24V EN54-4 Switch Mode PSU in Metal Enclosure
C-Tec- Certified to EN54-4/A2 by the LPCB and VdS.
- A powerful switch mode/digital hybrid PSU that can be customised* to suit your exact requirements - see More Information tab for details.
- Plastic cover on PSU PCB guards against touching live parts.
- Includes a single-pole voltfree changeover relay that switches for any fault condition.
- Multiple indicators - supply present, general fault, fault type & aux. equipment fault.
- Two selectable battery charge currents.
- Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
- Mains fail simulation mode.
- Improved on-board temperature sensor with optional remote sensor.
- Electronic functions comply with EN50131-6 grades 1-4 for security applications.
- BF562-1/E Encased PCBversion available.
-
C-TEC BS 5839-6 Hush Button
C-Tec- Fully Compliant with BS 5839 Part 6
- Works with Apollo XP95/Discovery and Hochiki ESP Protocols
- Fitted by a standard 25mm Back Box
- Built in Loop Isolator
-
C-Tec CASE 4-8 Way Sounder Controller, ZFP Panels Only
C-Tec- Supplies 4 or 8 monitored 12.5mA sounder circuits, extendable from 4 to 8 using a CA739PCB
- Includes an onboard short circuit loop isolator and space for an auxiliary 24V 1.5A power supply unit to boost alarm current
- Maintains independent open and short circuit monitoring for all sounder circuits, using one loop address per 4 circuits
-
C-Tec CAST 4 Way Conventional Zone Converter
C-Tec- Loop powered with an onboard short circuit loop isolator and four zone circuit isolators to maintain EN 54-2 compliance
- Supplied as a 4-zone unit, extendable to 8 zones using a CA740PCB extender PCB housed in the same enclosure with a separate loop address
- Ideal for retrofit sites where conventional devices are being replaced with addressable devices while retaining existing wiring, maintaining loop and individual zone circuit integrity
-
C-Tec CAST Base Sounder
C-Tec- Delivers a powerful 92dB(A) sound output at 1 meter, ensuring clear audibility in case of an alarm
- Equipped with an onboard short-circuit loop isolator to enhance system integrity and safety
- Offers flexibility with 4 selectable volume levels and 31 different tones to suit various environments and scenarios
-
C-Tec CAST Base Voice Sounder
C-Tec- Superb sound intelligibility for clear and effective communication during emergencies
- Onboard short-circuit loop isolator to maintain system integrity
- Four selectable volume levels to ensure optimal audibility in different environments
-
C-Tec CAST C-3-8 Base VAD
C-Tec- Onboard short-circuit loop isolator for enhanced system resilience
- Incorporates a short-circuit loop isolator and group addressing capability
- Group addressing facility allows simultaneous operation of multiple devices
-
C-Tec CAST C-3-8 Base VAD with Sounder
C-Tec- Provides 'C-3-8' rated light distribution and 92dB(A) sound output
- Incorporates a short-circuit loop isolator and group addressing capability
- Offers selectable volume levels, tones, and optional colored caps for stand-alone use
-
C-Tec CAST C-3-8 Base VAD with Voice Sounder
C-Tec- Provides 'C-3-8' rated light distribution for effective visual signaling
- Offers superb sound intelligibility with selectable voice messages and tones
- Incorporates an onboard short-circuit loop isolator for enhanced system resilience
-
C-Tec CAST Compact C-3-8 Ceiling VAD
C-Tec- Certified to EN54-17, EN54-23, and EN54-13 standards for fire alarm devices
- Offers C-3-8 light distribution when ceiling mounted and W-3-3.1 coverage when wall mounted
- Incorporates an onboard short-circuit loop isolator for enhanced system reliability
-
C-Tec CAST Compact C-3-8 Ceiling VAD with Sounder
C-Tec- Provides 'C-3-8' light distribution when ceiling mounted and 'W-3-3.1' coverage when wall mounted
- Delivers an impressive 96dB(A) sound output at 1 meter distance
- Incorporates an onboard short-circuit loop isolator and operates at low current consumption (12.5mA alarm, 460µA quiescent)
Low Stock
-
C-Tec CAST Compact Ceiling Sounder
C-Tec- Onboard short-circuit loop isolator for enhanced system resilience
- Low current consumption with 5.5mA typical alarm current and 460µA quiescent current
- Flexible configuration with 4 selectable volume levels, 31 tones, and group addressing capability
-
C-Tec CAST Detector Base
C-Tec- The CA408 is third-party LPCB certified to the relevant parts of EN54 standards
- It offers a simple "click and twist" design for easy installation and can be ceiling-mounted in any orientation
- The base is also compatible with C-TEC's CAST protocol sounder VADs and can connect to a remote LED indicator
-
C-Tec CAST Handheld Device Programmer & Testing Tool
C-Tec- Assigns CAST detectors, call points, sounders, VADs, and interface units with a User ID in seconds
- Allows testing of CAST device outputs by activating sounders, VADs, or relays, and testing inputs by detecting alarm conditions
- Battery-powered with auto-shutdown to preserve battery life and backlit LCD with adjustable contrast
-
C-Tec CAST Hi-Output W-2.75-9 Wall VAD with Sounder
C-Tec- Provides a 'W-2.75-9' rated light distribution, ensuring effective visual coverage over a 2.75m x 9m area, and is also rated as a W-4-4 VAD
- Delivers an impressive 103dB(A) sound output at 1m distance, ensuring audible coverage in noisy environments
- Incorporates an onboard short-circuit loop isolator for enhanced system resilience
-
C-Tec CAST Hi-Output W-2.75-9 Wall VAD with Voice Sounder
C-Tec- Provides excellent sound intelligibility with selectable volume levels and pre-recorded messages/tones
- Incorporates an onboard short-circuit loop isolator for enhanced system resilience
- Offers flexible light coverage options, rated as 'W-2.75-9' or 'W-4-4' for wall mounting
-
C-Tec CAST Hi-Output Wall Sounder
C-Tec- It has an onboard short-circuit loop isolator for enhanced system reliability
- It offers 4 selectable volume levels and 31 selectable tones for versatile configuration
- With an IP55 rating, it is suitable for outdoor installation in covered areas
-
C-Tec CAST Hi-Output Wall Voice Sounder
C-Tec- Superb sound intelligibility with six selectable messages and tones
- Onboard short-circuit loop isolator for enhanced system reliability
- Four selectable volume levels to suit different environments
-
C-Tec CAST Indoor Manual Call Point
C-Tec- It is surface or flush mountable and features an onboard short-circuit loop isolator
- The smooth-action resettable element mimics the feel of breaking glass, and a red LED 'alarm ring' illuminates the call point face upon activation
- The photoluminescent operating window remains visible for up to 5 minutes, and the device is available in various colors
-
C-Tec CAST Input Output Module
C-Tec- It can monitor up to 20 conventional detectors, 10 manual call points, and any normally open switch with an EOL resistor or a simple normally open or closed switch
- It incorporates an onboard short-circuit loop isolator and has a low typical alarm current of 5.5mA (1.3mA quiescent) at 22-40V DC
- It can switch 1A@30V DC (or 0.3A@125V AC) and includes volt-free changeover contacts for triggering devices like roller-shutter doors, gas shut-off valves, and smoke vents
Low Stock
-
C-Tec CAST Mains Switching Input Output Module
C-Tec- Certified to EN54-17, EN54-18, and EN54-13 standards for fire alarm systems
- Monitors up to 20 conventional detectors, 10 manual call points, and various switch types
- Includes volt-free changeover contacts for triggering external devices like roller shutters, gas valves, and smoke vents
-
C-Tec CAST Mini I/O Unit
C-Tec- It can monitor up to 20 conventional detectors, 10 manual call points, and any normally open switch with an EOL resistor or a simple normally open or closed switch
- It incorporates an onboard short-circuit loop isolator and has a low typical alarm current of 5.5mA (1.3mA quiescent) at 22-40V DC
- It can switch 1A@30V DC (or 0.3A@125V AC) and includes volt-free changeover contacts for triggering devices like roller-shutter doors, gas shut-off valves, and smoke vents
-
C-Tec CAST O-R-3-2.5-18 Base Corridor VAD
C-Tec- Provides 'O-R-3-2.5-18' rated light distribution, ideal for corridors up to 2.5m wide and 18m long
- Incorporates an onboard short-circuit loop isolator
- Offers low current consumption with 7mA typical alarm current and 460µA typical quiescent current at 27-40V DC
-
C-Tec CAST O-R-3-2.5-18 Base Corridor VAD with Sounder
C-Tec- Provides 'O-R-3-2.5-18' rated light distribution, ideal for corridors with 2.5m width and 18m length coverage
- Delivers 92dB(A) sound output at 1m distance, with an onboard short-circuit loop isolator
- Offers 4 selectable volume levels, 31 selectable tones, and group addressing for simultaneous operation of multiple devices
-
C-Tec CAST O-R-3-2.5-18 Base VAD with Voice Sounder
C-Tec- Rated for corridors up to 2.5m wide and 18m long with specific mounting orientation
- Offers six selectable voice messages with tones, including evacuate, alert, and system test messages
- Incorporates an onboard short-circuit loop isolator and four selectable volume levels for versatile installation
-
C-Tec CAST Outdoor Manual Call Point
C-Tec- It has an onboard short-circuit loop isolator to maintain system integrity
- The smooth-action resettable element mimics the feel of breaking glass
- It is supplied with a reset/back box removal key and a 'Not in Use' label
-
C-Tec CAST Sounder Control Module
C-Tec- Monitors the sounder circuit for open and short circuit faults
- Provides up to 50mA output current from the CAST addressable loop
- Includes a short circuit loop isolator
-
C-Tec CAST Weatherproof Hi-Output W-2.75-9 Wall VAD with Sounder
C-Tec- It provides a wide light distribution coverage rated W-2.75-9 and W-4-4, ensuring effective visual alarm signalingt
- With an impressive 103dB(A) sound output at 1 meter, it delivers high audibility for emergency notifications
- It offers versatility with selectable volume levels, tones, and the ability to group multiple devices for simultaneous operation
-
C-Tec CAST Weatherproof Hi-Output Wall Sounder
C-Tec- Impressive 100dB(A) sound output at 1m distance, ensuring audible alerts in outdoor environments
- Onboard short-circuit loop isolator for enhanced system reliability
- Selectable options including 4 volume levels and 31 tones, allowing customization to specific requirements
-
C-Tec CAST Zone Monitor Module
C-Tec- LPCB certified to EN54-17 & 18 and Kiwa Telefication certified to EN54-13 for compliance with industry standards
- Onboard short-circuit loop isolator for enhanced system reliability
- Mountable on a standard UK 25mm double gang back box for easy installation
-
C-Tec CFP 2, 4 or 8 Zone Conventional Fire Panel
C-Tec- LPCB certified to EN54 Parts 2 and 4.
- 2, 4 or 8 zone circuits.
- Economy version available.
- Four conventional sounder circuits.
-
C-Tec CFP 8 Zone Conventional Repeater Panel
C-Tec- Repeats functions of mater CFP panel (Standard Conventional or AlarmSense).
- Up to 8 repeaters per CFP master.
- Includes its own Mains power supply that requires its own standby battery supply.