Aspirating Smoke Detection
Aspiration smoke detection (ASD) is a sophisticated fire detection technology that provides early warning of a potential fire. Unlike traditional smoke detectors, which rely on detecting smoke particles in the air, aspiration smoke detectors draw in air through a network of pipes or tubing to detect smoke particles at a very early stage of a fire. The technology is based on the principle of continuously sampling air from a protected area and analysing it for the presence of smoke particles.
Know what you're looking for?
Showing 101–121 of 121 results
-
The Blazer: Automatic Aspirating Maintenance System
Vesda- Reduces filter replacement
- Reduces the wear and tear of the ASD
- Stops the transport and lifting of vacuums and compressors
- Reduces call outs caused by flow faults
- Lowers the overall cost to maintain
-
Vesda 855 In-line Filter Element, Sold in packs of 4
Vesda- Suitable for all Xtralis Aspirating Smoke Detectors.
- Improved detector longevity in applications with high levels of air-borne contamination.
- Reduces maintenance intervals, thus reducing total cost of ownership.
- Requires no additional pipe fi ttings thus reducing cost of installation.
- Improved aesthetics.
- Vertical or horizontal mounting.
- Compatible with metric (25mm OD) and imperial (1” OD) pipes eliminating the need for pipe adaptors.
-
Vesda Filter Cartridge
Vesda- Easy swap replacement filter.
- Fits VLC, VLF, VLP and VLS VESDA detectors.
- Available singly or in packs of 20.
- One model fits all detectors.
-
VESDA LCD Programmer
Vesda- User friendly menu system
- Supports multiple languages
- Single point access to entire VESDAnet system
- Alarm and fault simulation
- Shows wiring order
- Locates communications failures
- Password security
- Hand held or remote mounting
- Automatic Logoff when inactive
- Backlit LCD screen
-
VESDA VLC (LaserCOMPACT) Aspirating Smoke Detector
Vesda- Suitable for Zone 2 applications (VLC-EX only).
- Absolute smoke detection (coverage of 800 m2 or 8,000 sq. ft).
- Wide sensitivity range (0.005 - 20% obscuration/m and 0.0015 - 6% obscuration/ft).
- Single pipe inlet.
Low Stock
-
VESDA VLF (LaserFOCUS) Aspirating Smoke Detector
Vesda- Suitable for 250 or 500m2 coverage.
- Out-of-the-box installation and commissioning.
- Pre-engineered pipe network designs.
- Programmable alarm thresholds.
-
VESDA VLI Industrial Aspirating Smoke Detector
Vesda- VESDA VLI laster industrial aspiration unit.
- Suitable for Class 1 Division 2 applications - Groups A,B,C & D.
- Up to 2000 m2 (21,520 sq. ft.) coverage.
- Up to 4 inlet pipes.
-
VESDA VLP (LaserPLUS) Aspirating Smoke Detector
Vesda- Wide sensitivity range.
- Laser based smoke detection.
- 4 configurable alarm levels.
- High efficiency aspirator.
- Four inlet pipes.
Low Stock
-
Vesda Xtralis Power Supplies
Vesda- Available in three sizes: 0.5 A / 7Ah, 0.5A / 14 Ah and 2 A / 38 Ah
- Temperature compensated charging to maximize battery life
- Designed to blend in with Xtralis detectors
- Knockouts designed to line up with Xtralis detectors
- External LED indication on 220E and 250E
- Internal LED indication on 215E
- Relay outputs for connection to the general-purpose input for fault monitoring.
- 230 Vac only
-
Vesda Xtralis VSP-850 In-Line Filter
Xtralis- Suitable for all Xtralis Aspirating Smoke Detectors.
- Improved detector longevity in applications with high levels of air-borne contamination.
- Reduces maintenance intervals, thus reducing total cost of ownership.
- Requires no additional pipe fittings thus reducing cost of installation.
-
VESDA-E Filter Cartridge
Vesda- Easy swap replacement filter.
- Suitable for use with VESDA-E VEP, VEU detectors.
- Available singly or in packs of 20.
-
VESDA-E STX Power Supply Unit
Xtralis- Available in 0.5 or 2.0 amp sizes.
- Choice of matt block or silver finish.
- Designed to blend in with VESDA-E detectors.
- Knockouts designed to line up with VESDA-E detectors.
-
Vesda-E VEA Addressable Aspirating Smoke Detector
Vesda- Pinpoint addressability.
- 40 addressable microbore tubes with individual sampling points.
- Assured detection with end to end system integrity monitoring.
- Interruption-free business operation with centralised testing and maintenance.
- Single sampling point or single tube blockage detection at set intervals.
-
VESDA-E VEP Aspirating Smoke Detector
Vesda- One and four pipe models for different applications.
- Flair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarms.
- Multi stage filtration and optical protection with clean air barriers ensures lifetime detection performance.
- Four alarm levels and a wide sensitivity range deliver optimum protection for the widest range of applications.
-
VESDA-E VES Aspirating Smoke Detector
Xtralis- Sector addressability for up to four sectors.
- 40/80/100 samplig holes based on A/B/C sensitivity.
- Adaptive scan threshold.
-
VESDA-E VEU Highest Sensitivity Aspirating Smoke Detector
Vesda- Premium detector of the VESDA-E range.
- Flair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarms.
- Multi stage filtration and optical protection with clean air barriers ensures lifetime detection performance.
- Four alarm levels and an ultra wide sensitivity range deliver optimum protection for the widest range of applications.
-
Wagner Titanus Micro Sens With Optional Room Identification
Wagner- The primary alarm can be set to sensitivity levels as high as 0.1 % obs./m.
- This air sampling smoke detector’s 40 to 50m-long pipe system can have up to eight air sampling points (5 with ROOM·IDENT).
- The TITANUS MICRO·SENS® has a wide range of options, so it can be customised to any number of situations.
- A second detector module can be incorporated to create a dual detector dependency configuration.
- Special versions are available for deep-freeze facilities (temperatures as low as -40 °C) and noise-critical areas (to 23 dB (A)).
- The plug-and-play system makes the air sampling smoke detector quick and easy to install.
- Maintenance work can be performed without entering the protected area.